C-Bus Wall Plate Saturn Enhanced Dynamic Labelling Technology, 5 key, Black grid

C-Bus Wall Plate Ocean Mist

Item Number: 5085EDLB-OM

Datasheet

PDF datasheet

For 5085EDLB-OM

Product Dimensions

Width icon

Width77 mm

Height icon

Height123 mm

Embedding depth icon

Embedding depth23.5 mm

Barcode

Qty UoM EAN Colour
1 9311554761387 Ocean Mist
8 19311554761384 Ocean Mist

Specifications

Design

Range

C-Bus

Product brand

Clipsal

Product or component type

wall plate

Device application

control

Colour

  • cover plate: ocean mist
  • grid: black

Product compatibility

LAN cable Cat. 5e

Physical

Provided equipment

  • mounting plate
  • flying lead

Control type

5 x push-button dual-action

Local signalling

status: LED (tri-colour) on push-button

Function of module

proximity sensor monitoring wake-up

Communication port protocol

C-Bus - 2 wires

Connector type

  • mini USB port (rear)
  • socket (rear) for C-Bus

Function available

firmware update by USB

Clamping connection capacity

0.2...1.5 mm²

Fixing mode

by screws

Mounting support

wall

Width

77 mm

Height

123 mm

Depth

35 mm

Embedding depth

23.5 mm

Ip degree of protection

IP20

Ambient air temperature for operation

5...45 °C

Product certifications

  • CE
  • RCM

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

X

Environmental disclosure

ENVPEP120702EN

Circularity profile

ENVEOLI1207002EN

Material

Material

glass
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Operating Manuals

  • Specification Guide

  • Application Notes

  • Declaration of Conformity

  • Software - Release

  • Page 2  /  48
  • Page 3  /  48
  • Page 4  /  48
  • Page 5  /  48
  • Page 6  /  48
  • Page 7  /  48
  • Page 8  /  48
  • Page 9  /  48
  • Page 10  /  48
  • Page 11  /  48
  • Page 12  /  48
  • Page 13  /  48
  • Page 14  /  48
  • Page 15  /  48
  • Page 16  /  48
  • Page 17  /  48
  • Page 18  /  48
  • Page 19  /  48
  • Page 20  /  48
  • Page 21  /  48
  • Page 22  /  48
  • Page 23  /  48
  • Page 24  /  48
  • Page 25  /  48
  • Page 26  /  48
  • Page 27  /  48
  • Page 28  /  48
  • Page 29  /  48
  • Page 30  /  48
  • Page 31  /  48
  • Page 32  /  48
  • Page 33  /  48
  • Page 34  /  48
  • Page 35  /  48
  • Page 36  /  48
  • Page 37  /  48
  • Page 38  /  48
  • Page 39  /  48
  • Page 40  /  48
  • Page 41  /  48
  • Page 42  /  48
  • Page 43  /  48
  • Page 44  /  48
  • Page 45  /  48
  • Page 46  /  48
  • Page 47  /  48
  • Page 48  /  48

Frequently Asked Questions

hide show

What is new of the C-Bus Toolkit 1.16.3?

What is new of the C-Bus Toolkit 1.16.3?
  • C-Bus Toolkit 1.16.3 was released on 26/06/2023

Clock Optimisation
When the network node is selected in the project tree, the summary information for the network now includes an additional line, Units with Clock, which displays how many units on the network have their clock enabled.

eDLT Firmware
The eDLT Firmware Updater has been updated to include firmware version 1.7.0. This firmware addresses an issue that affected commissioning of the unit via bridge networks. It also addresses an issue that resulted in increased network traffic.

C-Gate 2.11.10
This release includes C-Gate 2.11.10. For further details, refer to the C-Gate release notes later in this document.

Other Fixes
• TK-10683: Toolkit crashes when copying and pasting a lighting application.

C-Bus Toolkit 1.16.3 can be downloaded from SE Ecoxpert
https://ecoxpert.se.com/en/spacelogic-c-bus/software-and-firmware/software#tab/documents

How to update C-Bus eDLT Firmware

NOTE: The following procedure assumes that you have installed the latest version of C-Bus Toolkit which will contain the latest eDLT firmware. 

To update a C-Bus eDLT's firmware

1) Connect the working & powered eDLT to a PC/Laptop via a Mini USB cable
2) Open C-Bus Toolkit in the file menu options select Tools and eDLT Firmware Updater
3) Click on the folder/file selector ... in the eDLT Firmware Updater Dialog 
4) Select the latest version of eDLTFirmware located in the C-Bus Toolkits eDLT firmware directory - typically
C:\Clipsal\CBusToolkit\Firmware\eDLTFirmware
5) Click the Start Update button to start the firmware upgrade process
6) Await for the firmware upgrade process to complete, 
 

eDLT.JPG

Note: The eDLT firmware upgrade process requires a stable C-Bus network (if you are experiencing C-Bus communications issues you will likely experience issues upgrading the firmware) in these cases it may be better to have eDLT closer to C-Bus power supplies or if possible use a test bench C-Bus network to upgrade the eDLT firmware.


 

Toolkit showing no serial number and or display but disappears when toolkit scan is done. Unable to edit or program the unit.

If 5085edlt has the latest  firmware 1.6 and toolkit running is an earlier version than Toolkit V1.16.0 then you will have issues with programming them. Things expect are  i.e no serial number showing up on network scan or able to load up and program the unit.. 

advice to download and run C-Bus Toolkit 1.16.0 or later

No serial number

please see link for C-Bus software: https://www.se.com/ww/en/download/

C-Bus Toolkit 1.6.0 https://download.schneider-electric.com/files?p_Archive_Name=C-Bus-Toolkit_V1160.zip&p_enDocType=Software%20-%20Release&p_Doc_Ref=C-Bus-Toolkit_V1160