Video: How do I program and wire an ATV212 to run using 3-wire control?

FA274408

21 July 2022

Issue:
Configuring Altivar 212 Drives for 3-Wire Control

Product Line:
Altivar 212, Altivar

Environment:
All

Cause:
Need to use 3-wire (momentary) control 

Resolution:

Programming:
Press MODE key to AUF
Arrow down to F---, and  press ENT key
Set F111 to 2
Set F112 to 49

Wiring:
Wire the F terminal from a Normally Open (NO), momentary close, START contact
Wire the R terminal from a Normally Closed (NC), momentary open, STOP contact


 
;